{"id":3552,"date":"2013-04-09T11:33:55","date_gmt":"2013-04-09T11:33:55","guid":{"rendered":"http:\/\/transformadores.beinventia.com\/?p=656"},"modified":"2020-07-28T09:10:28","modified_gmt":"2020-07-28T12:10:28","slug":"repairing-transformers-leaking","status":"publish","type":"post","link":"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/","title":{"rendered":"Reparation of filtration to transformer or exterior mining substation ET company"},"content":{"rendered":"<p>Date: January 2010<\/p>\n<p>Company: ET \/ RANCAGUA \u2013 VI Region.<\/p>\n<p>Filtrations were repaired to the transformer or exterior mining substation:<\/p>\n<p>&#8211; Nitrogen pressure was applied to reduce the quantity of silicon of the transformer and to situate it under the line of insulators.<\/p>\n<p>&#8211; Change of base and cap packages of insulators in 4160V.<\/p>\n<p>&#8211; Tightening of caps of insulators 13200V.<\/p>\n<p>&#8211; Reincorporation of silicon apart to repair the transformer.<\/p>\n<p>&#8211; Refill with 210 l. dielectric silicon to reach the normal level.<\/p>\n<p>&#8211; By applying nitrogen pressure of 0.5kg\/cm2 it is verified that the transformer filtrations are repaired.<\/p>\n<p>&#8211; Measurement of the resistance of insulation:<\/p>\n<ol>\n<li>High voltage \u2013 Low voltage.<\/li>\n<li>High voltage \u2013 Mass.<\/li>\n<li>Low voltage \u2013 Mass.<\/li>\n<\/ol>\n<p>&#8211; Measure of the resistance of primary and secondary coils in the position of tap it was placed.<\/p>\n<p>&#8211; Measure of the reason of transformation in the position of tap it was placed.<\/p>\n\r\n\t\t\t\t<style type='text\/css'>\r\n\t\t\t\t\t\t#gallery-1 {\r\n\t\t\t\t\t\t\t\tmargin: auto;\r\n\t\t\t\t\t\t}\r\n\t\t\t\t\t\t#gallery-1 .gallery-item {\r\n\t\t\t\t\t\t\t\tfloat: left;\r\n\t\t\t\t\t\t\t\tmargin-top: 10px;\r\n\t\t\t\t\t\t\t\ttext-align: center;\r\n\t\t\t\t\t\t\t\twidth: 25%;\r\n\t\t\t\t\t\t}\r\n\t\t\t\t\t\t#gallery-1 img {\r\n\t\t\t\t\t\t\t\tborder: 2px solid #cfcfcf;\r\n\t\t\t\t\t\t}\r\n\t\t\t\t\t\t#gallery-1 .gallery-caption {\r\n\t\t\t\t\t\t\t\tmargin-left: 0;\r\n\t\t\t\t\t\t}\r\n\t\t\t\t<\/style>\r\n\t\t\t\t<!-- see gallery_shortcode() in wp-includes\/media.php -->\n\t\t<div id='gallery-1' class='gallery galleryid-7721 gallery-columns-4 gallery-size-thumbnail dt-gallery-container'><dl class='gallery-item'>\r\n\t\t\t\t\t\t<dt class='gallery-icon'>\r\n\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-aisladores-secundario-filtracion-reparada-4ecf8181bd980.jpg\" class=\"rollover rollover-zoom dt-mfp-item mfp-image\" title=\"Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-aisladores-secundario-filtracion-reparada-4ecf8181bd980\" data-dt-img-description=\"\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-aisladores-secundario-filtracion-reparada-4ecf8181bd980-150x150.jpg\" height=\"150\" width=\"150\" alt=\"\"><\/a>\r\n\t\t\t\t\t\t<\/dt><\/dl><dl class='gallery-item'>\r\n\t\t\t\t\t\t<dt class='gallery-icon'>\r\n\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-caja-de-baja-tension-del-transformador-4ecf8119b2135.jpg\" class=\"rollover rollover-zoom dt-mfp-item mfp-image\" title=\"Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-caja-de-baja-tension-del-transformador-4ecf8119b2135\" data-dt-img-description=\"\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-caja-de-baja-tension-del-transformador-4ecf8119b2135-150x150.jpg\" height=\"150\" width=\"150\" alt=\"\"><\/a>\r\n\t\t\t\t\t\t<\/dt><\/dl><dl class='gallery-item'>\r\n\t\t\t\t\t\t<dt class='gallery-icon'>\r\n\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-estado-de-empaquetaduras-4ecf803669d2c.jpg\" class=\"rollover rollover-zoom dt-mfp-item mfp-image\" title=\"Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-estado-de-empaquetaduras-4ecf803669d2c\" data-dt-img-description=\"\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-estado-de-empaquetaduras-4ecf803669d2c-150x150.jpg\" height=\"150\" width=\"150\" alt=\"\"><\/a>\r\n\t\t\t\t\t\t<\/dt><\/dl><dl class='gallery-item'>\r\n\t\t\t\t\t\t<dt class='gallery-icon'>\r\n\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-estado-inicial-de-transformador-4ecf7ee0540a7.jpg\" class=\"rollover rollover-zoom dt-mfp-item mfp-image\" title=\"Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-estado-inicial-de-transformador-4ecf7ee0540a7\" data-dt-img-description=\"\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-estado-inicial-de-transformador-4ecf7ee0540a7-150x150.jpg\" height=\"150\" width=\"150\" alt=\"\"><\/a>\r\n\t\t\t\t\t\t<\/dt><\/dl><br style=\"clear: both\" \/><dl class='gallery-item'>\r\n\t\t\t\t\t\t<dt class='gallery-icon'>\r\n\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-instalacion-de-valvulas-presion-vacio-4ecf7f4a56d3a.jpg\" class=\"rollover rollover-zoom dt-mfp-item mfp-image\" title=\"Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-instalacion-de-valvulas-presion-vacio-4ecf7f4a56d3a\" data-dt-img-description=\"\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-instalacion-de-valvulas-presion-vacio-4ecf7f4a56d3a-150x150.jpg\" height=\"150\" width=\"150\" alt=\"\"><\/a>\r\n\t\t\t\t\t\t<\/dt><\/dl>\r\n\t\t\t\t\t\t<br style='clear: both;' \/>\r\n\t\t\t\t<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p><!--:es-->Reparaci\u00f3n de filtraci\u00f3n de silicona a transformadores<!--:--><!--:en-->Repair of leakage of silicone to transformers<!--:--><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[173],"tags":[],"class_list":["post-3552","post","type-post","status-publish","format-standard","hentry","category-proyects","description-off"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.4 (Yoast SEO v25.6) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Outside mine Transformers repairing | Transformadores CH<\/title>\n<meta name=\"description\" content=\"We offer many services about maintenance and transformer repair. Contact us to learn more.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reparation of filtration to transformer or exterior mining substation ET company\" \/>\n<meta property=\"og:description\" content=\"We offer many services about maintenance and transformer repair. Contact us to learn more.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/\" \/>\n<meta property=\"og:site_name\" content=\"Transformadores 2015\" \/>\n<meta property=\"article:published_time\" content=\"2013-04-09T11:33:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-07-28T12:10:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-aisladores-secundario-filtracion-reparada-4ecf8181bd980-150x150.jpg\" \/>\n<meta name=\"author\" content=\"cromero\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"cromero\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/\"},\"author\":{\"name\":\"cromero\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/#\/schema\/person\/8a095be20b10c70aac5faeb348f1131c\"},\"headline\":\"Reparation of filtration to transformer or exterior mining substation ET company\",\"datePublished\":\"2013-04-09T11:33:55+00:00\",\"dateModified\":\"2020-07-28T12:10:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/\"},\"wordCount\":161,\"publisher\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/#organization\"},\"articleSection\":[\"Proyects\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/\",\"url\":\"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/\",\"name\":\"Outside mine Transformers repairing | Transformadores CH\",\"isPartOf\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/#website\"},\"datePublished\":\"2013-04-09T11:33:55+00:00\",\"dateModified\":\"2020-07-28T12:10:28+00:00\",\"description\":\"We offer many services about maintenance and transformer repair. Contact us to learn more.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/www.transformadores.cl\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Reparation of filtration to transformer or exterior mining substation ET company\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/#website\",\"url\":\"https:\/\/www.transformadores.cl\/en\/\",\"name\":\"Transformadores CH\",\"description\":\"Fabricaci\u00f3n de transformadores industriales\",\"publisher\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.transformadores.cl\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/#organization\",\"name\":\"Transformadores CH\",\"url\":\"https:\/\/www.transformadores.cl\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/05\/logo.png\",\"contentUrl\":\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/05\/logo.png\",\"width\":206,\"height\":76,\"caption\":\"Transformadores CH\"},\"image\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/transformadores-ch-s.a.\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/#\/schema\/person\/8a095be20b10c70aac5faeb348f1131c\",\"name\":\"cromero\",\"url\":\"https:\/\/www.transformadores.cl\/en\/author\/cromero\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Outside mine Transformers repairing | Transformadores CH","description":"We offer many services about maintenance and transformer repair. Contact us to learn more.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/","og_locale":"en_US","og_type":"article","og_title":"Reparation of filtration to transformer or exterior mining substation ET company","og_description":"We offer many services about maintenance and transformer repair. Contact us to learn more.","og_url":"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/","og_site_name":"Transformadores 2015","article_published_time":"2013-04-09T11:33:55+00:00","article_modified_time":"2020-07-28T12:10:28+00:00","og_image":[{"url":"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2013\/04\/Servicios-Transformadores-CH-terreno-mantenciones-y-diagnosticos-a-transformadores-aisladores-secundario-filtracion-reparada-4ecf8181bd980-150x150.jpg","type":"","width":"","height":""}],"author":"cromero","twitter_card":"summary_large_image","twitter_misc":{"Written by":"cromero","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/#article","isPartOf":{"@id":"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/"},"author":{"name":"cromero","@id":"https:\/\/www.transformadores.cl\/en\/#\/schema\/person\/8a095be20b10c70aac5faeb348f1131c"},"headline":"Reparation of filtration to transformer or exterior mining substation ET company","datePublished":"2013-04-09T11:33:55+00:00","dateModified":"2020-07-28T12:10:28+00:00","mainEntityOfPage":{"@id":"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/"},"wordCount":161,"publisher":{"@id":"https:\/\/www.transformadores.cl\/en\/#organization"},"articleSection":["Proyects"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/","url":"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/","name":"Outside mine Transformers repairing | Transformadores CH","isPartOf":{"@id":"https:\/\/www.transformadores.cl\/en\/#website"},"datePublished":"2013-04-09T11:33:55+00:00","dateModified":"2020-07-28T12:10:28+00:00","description":"We offer many services about maintenance and transformer repair. Contact us to learn more.","breadcrumb":{"@id":"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.transformadores.cl\/en\/proyects\/repairing-transformers-leaking\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.transformadores.cl\/en\/"},{"@type":"ListItem","position":2,"name":"Reparation of filtration to transformer or exterior mining substation ET company"}]},{"@type":"WebSite","@id":"https:\/\/www.transformadores.cl\/en\/#website","url":"https:\/\/www.transformadores.cl\/en\/","name":"Transformadores CH","description":"Fabricaci\u00f3n de transformadores industriales","publisher":{"@id":"https:\/\/www.transformadores.cl\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.transformadores.cl\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.transformadores.cl\/en\/#organization","name":"Transformadores CH","url":"https:\/\/www.transformadores.cl\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.transformadores.cl\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/05\/logo.png","contentUrl":"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/05\/logo.png","width":206,"height":76,"caption":"Transformadores CH"},"image":{"@id":"https:\/\/www.transformadores.cl\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/transformadores-ch-s.a.\/"]},{"@type":"Person","@id":"https:\/\/www.transformadores.cl\/en\/#\/schema\/person\/8a095be20b10c70aac5faeb348f1131c","name":"cromero","url":"https:\/\/www.transformadores.cl\/en\/author\/cromero\/"}]}},"_links":{"self":[{"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/posts\/3552","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/comments?post=3552"}],"version-history":[{"count":4,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/posts\/3552\/revisions"}],"predecessor-version":[{"id":6270,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/posts\/3552\/revisions\/6270"}],"wp:attachment":[{"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/media?parent=3552"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/categories?post=3552"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/tags?post=3552"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}