{"id":3609,"date":"2015-06-17T12:02:14","date_gmt":"2015-06-17T12:02:14","guid":{"rendered":"http:\/\/www.transformadores.cl\/?p=3609"},"modified":"2017-05-26T05:50:51","modified_gmt":"2017-05-26T08:50:51","slug":"switching-and-measurement-cell","status":"publish","type":"post","link":"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/","title":{"rendered":"Switching and Measurement cell"},"content":{"rendered":"<p><strong>Switching and Measurement cell<\/strong> Switching and Measurement cell immersed in coolant biodegradable &#8220;FR3&#8221; 24 kV class, 80 amps, has the following characteristics: &#8211; One (1) isolated three-phase input 24 kV class, type bushing inserts (MUFAs include elbow) with enclosure protection and cable ties. &#8211; One (1) general disconnect under load class 24 kV FR3 immersed in vegetable oil. &#8211; Game (3) of Bayonet Fuse Holders, as general protection. Includes 3 fuses additional parts. &#8211; A compact measuring 2 elements, 23000\/120 volts, 40-80\/5 amps, FR3 embedded in the interior of the cell. &#8211; Electronic billing meter for active and reactive power, multirate, wireless indirect model ZMD405CT44.0007, 5A 240\/415V 3&#215;58\/100 with certification. &#8211; One (1) isolated three-phase output 24 kV class, type bushing inserts (MUFAs include elbow), with cabinet protection and cable ties. &#8211; Cover front protection. &#8211; Built-level sight glass, pressure relief valve on top, filling nipple, valve Drain and sampling, ground, and lifting lugs for anchoring base. &#8211; Testing electrical laboratory certificate issuance CH. Blasting treatment is done to the pond, prior to applying anti-rust paint zinc epoxy and polyurethane enamel finish outdoors type, pearl gray (another color on demand).<\/p>\n\r\n\t\t\t\t<style type='text\/css'>\r\n\t\t\t\t\t\t#gallery-1 {\r\n\t\t\t\t\t\t\t\tmargin: auto;\r\n\t\t\t\t\t\t}\r\n\t\t\t\t\t\t#gallery-1 .gallery-item {\r\n\t\t\t\t\t\t\t\tfloat: left;\r\n\t\t\t\t\t\t\t\tmargin-top: 10px;\r\n\t\t\t\t\t\t\t\ttext-align: center;\r\n\t\t\t\t\t\t\t\twidth: 25%;\r\n\t\t\t\t\t\t}\r\n\t\t\t\t\t\t#gallery-1 img {\r\n\t\t\t\t\t\t\t\tborder: 2px solid #cfcfcf;\r\n\t\t\t\t\t\t}\r\n\t\t\t\t\t\t#gallery-1 .gallery-caption {\r\n\t\t\t\t\t\t\t\tmargin-left: 0;\r\n\t\t\t\t\t\t}\r\n\t\t\t\t<\/style>\r\n\t\t\t\t<!-- see gallery_shortcode() in wp-includes\/media.php -->\n\t\t<div id='gallery-1' class='gallery galleryid-7853 gallery-columns-4 gallery-size-thumbnail dt-gallery-container'><dl class='gallery-item'>\r\n\t\t\t\t\t\t<dt class='gallery-icon'>\r\n\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/06\/Celda-de-maniobra.jpg\" class=\"rollover rollover-zoom dt-mfp-item mfp-image\" title=\"Celda-de-maniobra\" data-dt-img-description=\"\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/06\/Celda-de-maniobra-150x136.jpg\" height=\"150\" width=\"136\" alt=\"\"><\/a>\r\n\t\t\t\t\t\t<\/dt><\/dl><dl class='gallery-item'>\r\n\t\t\t\t\t\t<dt class='gallery-icon'>\r\n\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/06\/Celda-de-maniobra2.jpg\" class=\"rollover rollover-zoom dt-mfp-item mfp-image\" title=\"Celda-de-maniobra2\" data-dt-img-description=\"\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/06\/Celda-de-maniobra2-150x150.jpg\" height=\"150\" width=\"150\" alt=\"\"><\/a>\r\n\t\t\t\t\t\t<\/dt><\/dl>\r\n\t\t\t\t\t\t<br style='clear: both;' \/>\r\n\t\t\t\t<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Switching and Measurement cell Switching and Measurement cell immersed in coolant biodegradable &#8220;FR3&#8221; 24 kV class, 80 amps, has the following characteristics: &#8211; One (1) isolated three-phase input 24 kV class, type bushing inserts (MUFAs include elbow) with enclosure protection and cable ties. &#8211; One (1) general disconnect under load class 24 kV FR3 immersed&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[180,188],"tags":[],"class_list":["post-3609","post","type-post","status-publish","format-standard","hentry","category-m-t-cells-and-l-v","category-no-category","description-off"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.4 (Yoast SEO v25.6) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Switching and Measurement cell | Transformadores 2015<\/title>\n<meta name=\"robots\" content=\"noindex, follow\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Switching and Measurement cell\" \/>\n<meta property=\"og:description\" content=\"Switching and Measurement cell Switching and Measurement cell immersed in coolant biodegradable &#8220;FR3&#8221; 24 kV class, 80 amps, has the following characteristics: &#8211; One (1) isolated three-phase input 24 kV class, type bushing inserts (MUFAs include elbow) with enclosure protection and cable ties. &#8211; One (1) general disconnect under load class 24 kV FR3 immersed&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/\" \/>\n<meta property=\"og:site_name\" content=\"Transformadores 2015\" \/>\n<meta property=\"article:published_time\" content=\"2015-06-17T12:02:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-05-26T08:50:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/06\/Celda-de-maniobra-150x136.jpg\" \/>\n<meta name=\"author\" content=\"cromero\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"cromero\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/\"},\"author\":{\"name\":\"cromero\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/#\/schema\/person\/8a095be20b10c70aac5faeb348f1131c\"},\"headline\":\"Switching and Measurement cell\",\"datePublished\":\"2015-06-17T12:02:14+00:00\",\"dateModified\":\"2017-05-26T08:50:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/\"},\"wordCount\":188,\"publisher\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/#organization\"},\"articleSection\":[\"M.T Cells and L.V\",\"No category\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/\",\"url\":\"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/\",\"name\":\"Switching and Measurement cell | Transformadores 2015\",\"isPartOf\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/#website\"},\"datePublished\":\"2015-06-17T12:02:14+00:00\",\"dateModified\":\"2017-05-26T08:50:51+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/www.transformadores.cl\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Switching and Measurement cell\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/#website\",\"url\":\"https:\/\/www.transformadores.cl\/en\/\",\"name\":\"Transformadores CH\",\"description\":\"Fabricaci\u00f3n de transformadores industriales\",\"publisher\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.transformadores.cl\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/#organization\",\"name\":\"Transformadores CH\",\"url\":\"https:\/\/www.transformadores.cl\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/05\/logo.png\",\"contentUrl\":\"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/05\/logo.png\",\"width\":206,\"height\":76,\"caption\":\"Transformadores CH\"},\"image\":{\"@id\":\"https:\/\/www.transformadores.cl\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/transformadores-ch-s.a.\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.transformadores.cl\/en\/#\/schema\/person\/8a095be20b10c70aac5faeb348f1131c\",\"name\":\"cromero\",\"url\":\"https:\/\/www.transformadores.cl\/en\/author\/cromero\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Switching and Measurement cell | Transformadores 2015","robots":{"index":"noindex","follow":"follow"},"og_locale":"en_US","og_type":"article","og_title":"Switching and Measurement cell","og_description":"Switching and Measurement cell Switching and Measurement cell immersed in coolant biodegradable &#8220;FR3&#8221; 24 kV class, 80 amps, has the following characteristics: &#8211; One (1) isolated three-phase input 24 kV class, type bushing inserts (MUFAs include elbow) with enclosure protection and cable ties. &#8211; One (1) general disconnect under load class 24 kV FR3 immersed&hellip;","og_url":"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/","og_site_name":"Transformadores 2015","article_published_time":"2015-06-17T12:02:14+00:00","article_modified_time":"2017-05-26T08:50:51+00:00","og_image":[{"url":"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/06\/Celda-de-maniobra-150x136.jpg","type":"","width":"","height":""}],"author":"cromero","twitter_card":"summary_large_image","twitter_misc":{"Written by":"cromero","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/#article","isPartOf":{"@id":"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/"},"author":{"name":"cromero","@id":"https:\/\/www.transformadores.cl\/en\/#\/schema\/person\/8a095be20b10c70aac5faeb348f1131c"},"headline":"Switching and Measurement cell","datePublished":"2015-06-17T12:02:14+00:00","dateModified":"2017-05-26T08:50:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/"},"wordCount":188,"publisher":{"@id":"https:\/\/www.transformadores.cl\/en\/#organization"},"articleSection":["M.T Cells and L.V","No category"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/","url":"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/","name":"Switching and Measurement cell | Transformadores 2015","isPartOf":{"@id":"https:\/\/www.transformadores.cl\/en\/#website"},"datePublished":"2015-06-17T12:02:14+00:00","dateModified":"2017-05-26T08:50:51+00:00","breadcrumb":{"@id":"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.transformadores.cl\/en\/m-t-cells-and-l-v\/switching-and-measurement-cell\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/www.transformadores.cl\/en\/"},{"@type":"ListItem","position":2,"name":"Switching and Measurement cell"}]},{"@type":"WebSite","@id":"https:\/\/www.transformadores.cl\/en\/#website","url":"https:\/\/www.transformadores.cl\/en\/","name":"Transformadores CH","description":"Fabricaci\u00f3n de transformadores industriales","publisher":{"@id":"https:\/\/www.transformadores.cl\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.transformadores.cl\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.transformadores.cl\/en\/#organization","name":"Transformadores CH","url":"https:\/\/www.transformadores.cl\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.transformadores.cl\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/05\/logo.png","contentUrl":"https:\/\/www.transformadores.cl\/wp-content\/uploads\/2015\/05\/logo.png","width":206,"height":76,"caption":"Transformadores CH"},"image":{"@id":"https:\/\/www.transformadores.cl\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/transformadores-ch-s.a.\/"]},{"@type":"Person","@id":"https:\/\/www.transformadores.cl\/en\/#\/schema\/person\/8a095be20b10c70aac5faeb348f1131c","name":"cromero","url":"https:\/\/www.transformadores.cl\/en\/author\/cromero\/"}]}},"_links":{"self":[{"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/posts\/3609","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/comments?post=3609"}],"version-history":[{"count":2,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/posts\/3609\/revisions"}],"predecessor-version":[{"id":4513,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/posts\/3609\/revisions\/4513"}],"wp:attachment":[{"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/media?parent=3609"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/categories?post=3609"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.transformadores.cl\/en\/wp-json\/wp\/v2\/tags?post=3609"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}